SpectraPro Series from
Princeton Instruments
Flat-Field Imaging Spectrographs optimized for CCD
Spectroscopy
Upgradable to double or triple spectrograph
Image corrected and optimized for CCD spectroscopy
Multiple Interchangeable turret
Stepping motor scanning system with microprocessor control
Optional internal shutter, six position filter wheel and
precision motorized slits
USB 2.0 computer interfaces
Stand alone SpectraPro scan control software
LabView, Visual Basic, C++
See Also: | Grating Chart
| Grating Calculator | Select the Proper
Grating | Accessories
| Accessories
Brochure
For an actual configuration move your mouse over
a model number and click on to download a corresponding data
sheet.
Port Configuration Diagram
Model
Grating
150g/mm
Grating
300g/mm
Grating
600g/mm
Grating
1200g/mm
Grating
1800 g/mm
Grating
2400 g/mm
Mode
Entrance Slit
Exit Slit
CCD Port
150mm
SpectraPro 2150 i - Focal
Length 150mm - f/4
Gratings (32 x 32mm) for SP-2150
Ruled, 50 G/mm with 600nm blaze wavelength
Ruled, 150 G/mm with 300nm blaze wavelength
Ruled, 150 G/mm with 500nm blaze wavelength
Ruled, 150 G/mm with 800nm blaze wavelength
Ruled, 150 G/mm with 4um blaze wavelength
Ruled, 300 G/mm with 300nm blaze wavelength
Ruled, 300 G/mm with 500nm blaze wavelength
Ruled, 300 G/mm with 750nm blaze wavelength
Ruled, 300 G/mm with 1um blaze wavelength
Ruled, 300 G/mm with 2um blaze wavelength
Ruled, 600 G/mm with 300nm blaze wavelength
Ruled, 600 G/mm with 500nm blaze wavelength
Ruled, 600 G/mm with 750nm blaze wavelength
Ruled, 600 G/mm with 1um blaze wavelength
Ruled, 600 G/mm with 1.6um blaze wavelength
Holographic, 1200 G/mm, UV optimized
Ruled, 1200 G/mm with 300nm blaze wavelength
Ruled, 1200 G/mm with 500nm blaze wavelength
Holographic, 1200 G/mm, Visible optimized
Ruled, 1200 G/mm with 750nm blaze wavelength
Holographic, 1800 G/mm, UV optimized
Ruled, 1800 G/mm with 500nm blaze wavelength
Ruled, 2400 G/mm with 240nm blaze wavelength
Holographic, 2400 G/mm, UV optimized
Holographic, 2400G/mm, VIS optimized
Ruled, 3600G/mm with 240nm blaze wavelength
Holographic, 3600 G/mm, UV optimized
SP-2155
0.8
nm/pixel
0.38
nm/pixel
0.18
nm/pixel
0.08
nm/pixel
0.044
nm/pixel
0.024
nm/pixel
Monochromator
side
front
SP-2156
Spectrograph
side
CCD port
300mm
SpectraPro 2300i -Focal Length
300 mm - f/3.9
Gratings (68 x 68mm) for SP-2300
Ruled, 150 G/mm with 300nm blaze wavelength.
Ruled, 150 G/mm with 4um blaze wavelength.
Ruled, 150 G/mm with 500nm blaze wavelength.
Ruled, 150 G/mm with 800nm blaze wavelength.
Ruled, 300 G/mm with 1um blaze wavelength.
Ruled, 300 G/mm with 2um blaze wavelength.
Ruled, 300 G/mm with 300nm blaze wavelength.
Ruled, 300 G/mm with 500nm blaze wavelength.
Ruled, 50 G/mm with 600nm blaze wavelength.
Ruled, 600 G/mm with 1um blaze wavelength.
Ruled, 600 G/mm with 1.6um blaze wavelength.
Ruled, 600 G/mm with 300nm blaze wavelength.
Ruled, 600 G/mm with 500nm blaze wavelength.
Ruled, 75 G/mm with 8um blaze wavelength.
Ruled, 1200 G/mm with 300nm blaze wavelength.
Ruled, 1200 G/mm with 500nm blaze wavelength.
Ruled, 1200 G/mm with 750nm blaze wavelength.
Holographic, 1200 G/mm, UV optimized.
Holographic, 1200 G/mm, VIS optimized.
Ruled, 1800 G/mm with 500nm blaze wavelength.
Holographic, 1800 G/mm, UV optimized.
Ruled, 2400 G/mm with 240nm blaze wavelength.
Holographic, 2400 G/mm, UV optimized.
Holographic, 2400 G/mm, VIS optimized.
Ruled, 3600 G/mm with 240nm blaze wavelength.
Holographic, 3600G/mm, UV optimized.
SP-2355
0.42
nm/pixel
0.22
nm/pixel
0.1
nm/pixel
0.046
nm/pixel
0.028
nm/pixel
0.017
nm/pixel
Monochromator
side
front
SP-2356
Spectrograph
side
CCD port
SP-2357
Monochromator
side
front and side
SP-2358
Mono./Spectrograph
side
side / CCD port
SP-2360
Spectrograph
side
dual CCD ports
500mm SpectraPro 2500i
- Focal Length 500mm-f /6.5
Gratings (68 x 68mm) for SP-2500
Ruled, 150 G/mm with 300nm blaze wavelength.
Ruled, 150 G/mm with 4um blaze wavelength.
Ruled, 150 G/mm with 500nm blaze wavelength.
Ruled, 150 G/mm with 800nm blaze wavelength.
Ruled, 300 G/mm with 1um blaze wavelength.
Ruled, 300 G/mm with 2um blaze wavelength.
Ruled, 300 G/mm with 300nm blaze wavelength.
Ruled, 300 G/mm with 500nm blaze wavelength.
Ruled, 50 G/mm with 600nm blaze wavelength.
Ruled, 600 G/mm with 1um blaze wavelength.
Ruled, 600 G/mm with 1.6um blaze wavelength.
Ruled, 600 G/mm with 300nm blaze wavelength.
Ruled, 600 G/mm with 500nm blaze wavelength.
Ruled, 75 G/mm with 8um blaze wavelength.
Ruled, 1200 G/mm with 300nm blaze wavelength.
Ruled, 1200 G/mm with 500nm blaze wavelength.
Ruled, 1200 G/mm with 750nm blaze wavelength.
Holographic, 1200 G/mm, UV optimized.
Holographic, 1200 G/mm, VIS optimized.
Ruled, 1800 G/mm with 500nm blaze wavelength.
Holographic, 1800 G/mm, UV optimized.
Ruled, 2400 G/mm with 240nm blaze wavelength.
Holographic, 2400 G/mm, UV optimized.
Holographic, 2400 G/mm, VIS optimized.
Ruled, 3600 G/mm with 240nm blaze wavelength.
Holographic, 3600G/mm, UV optimized.
SP-2555
0.26
nm/pixel
0.13
nm/pixel
0.064
nm/pixel
0.03
nm/pixel
0.018
nm/pixel
0.012
nm/pixel
Monochromator
side
front
SP-2556
Spectrograph
side
CCD port
SP-2556-9N
Spectrograph
front / side
CCD port
SP-2557
Monochromator
side
front and side
SP-2558
Mono./Spectrograph
side
side / CCD port
SP-2560
Spectrograph
side
dual CCD ports
750mm SpectraPro 2750
- Focal Length 750 mm - f/9.8
Gratings (68 x 68mm) for SP-7500
Ruled, 150 G/mm with 300nm blaze wavelength.
Ruled, 50 G/mm with 600nm blaze wavelength
Ruled, 150 G/mm with 300nm blaze wavelength
Ruled, 150 G/mm with 500nm blaze wavelength
Ruled, 150 G/mm with 800nm blaze wavelength
Ruled, 150 G/mm with 4um blaze wavelength
Ruled, 300 G/mm with 300nm blaze wavelength
Ruled, 300 G/mm with 500nm blaze wavelength
Ruled, 300 G/mm with 750nm blaze wavelength
Ruled, 300 G/mm with 1um blaze wavelength
Ruled, 300 G/mm with 2um blaze wavelength
Ruled, 600 G/mm with 300nm blaze wavelength
Ruled, 600 G/mm with 500nm blaze wavelength
Ruled, 600 G/mm with 750nm blaze wavelength
Ruled, 600 G/mm with 1um blaze wavelength
Ruled, 600 G/mm with 1.6um blaze wavelength
Holographic, 1200 G/mm, UV optimized
Ruled, 1200 G/mm with 300nm blaze wavelength
Ruled, 1200 G/mm with 500nm blaze wavelength
Holographic, 1200 G/mm, VIS optimized
Ruled, 1200 G/mm with 750nm blaze wavelength
Holographic, 1800 G/mm, UV optimized
Ruled, 1800 G/mm with 500nm blaze wavelength
Ruled, 2400 G/mm with 240nm blaze wavelength
Holographic, 2400 G/mm, UV optimized
Holographic, 2400 G/mm, VIS optimized
Ruled, 3600 G/mm with 240nm blaze wavelength
Holographic, 3600G/mm, UV optimized
Grating Installation Kit fors purchased after shipment.
SP-2755
0.176
nm/pixel
0.088
nm/pixel
0.044
nm/pixel
0.02
nm/pixel
0.012
nm/pixel
0.008
nm/pixel
Monochromator
side
front
SP-2756
Spectrograph
side
CCD port
SP-2756-9N
Spectrograph
front / side
CCD port
SP-2757
Monochromator
side
front and side
SP-2758
Mono./Spectrograph
side
side / CCD port
SP-2760
Spectrograph
side
dual CCD ports
All specifications stated for nm/Pixel @500 nm for a 20µm
Pixel CCD, 26 mm Length
Precision and Unlimited Versatility
The SpectraPro series of monochromator's and spectrographs
are recognized as industry standards for rugged, high-performance
operation and versatility. Each features an automated, multiple-grating
turret for extended spectral coverage. Four standard focal lengths
and a host of unique, customized features make SpectraPro spectrometers
ideal for environmental, industrial, educational, and research
applications. Through innovative engineering, these monochromator's
and spectrographs can be incorporated into completely integrated
spectroscopy systems customized to suit your specific application.
Higher Throughput
All SpectraPro monochromator's and spectrographs have high-aperture
optics, and feature corrected and computer-optimized optics to
reduce astigmatism. The SpectraPro models 300i, 500i, and 750
can be equipped with optional 68 x 84-mms to ensure that
the full aperture of the spectrometer is maintained even at longer
wavelengths. Other spectrometers typically suffer as much as a
30% loss in aperture at the longer wavelengths. All SpectraPro
monochromator's and spectrographs also feature enhanced UV-to-VIS
reflective coatings with 90% or better average reflectance. Specialized
gold and silver reflective coatings for IR and NIR wavelengths
are available as options.
No-Compromise Resolution
In high-aperture imaging spectrographs, the off-axis aberrations
can compromise system performance. The best focal plane for spectral
resolution is not the same as the best focal plane for spatial
resolution of multiple fiber inputs. Only SpectraPro offers interchangeable
focal-plane adapters optimized for your particular needs. Anything
less is a compromise in performance.
Positrack Interchange
The advantage of having a multiple-grating turret is to be
able to quickly changes. The wavelength of the spectrometer
from to interchange should be maintained to the
same precision as expected on a single.